RS20i Installation & Operating Guide Document # 9301H52900 Ver. 1.01
Use the Dest: box on the Ping Test to check the ‘gateway’ is ‘OK’.
If there is PC connected to the same LAN, open an internet browser and go to any public web
site such as http://www.datasatdigital.com
4. Planning a Simple Netwo
rk for Digital Cinema
All the network devices connected on a single network will have the same zone address and each
device will have its own network address.
Use a standard private network, for example 192.168.0.X (X can be in the range 1 – 254)
Most networks have a Gateway (sometimes called a router) which connects to other networks, eg to
the internet via the modem provided by the ISP. This is normally numbered either 1 or 254
Gateway = 192.168.0.1
The mask (also called the netmask) specifies the size of the network. For simple networks this is:
Mask = 255.255.255.0
There is a single address for devices to communicate with all other devices on the LAN at once.
This is the Broadcast Address. For simple networks, the first 3 number groups are the same as the IP
addresses and the 4th group is 255
Broadcast Addr = 192.168.0.255
Next assign a network address for each device in a logical and memorable way, for example:
Screen 1 RS20i 192.168.0.10
D-Cinema server 192.168.0.11
Digital Projector 192.168.0.12
Another network device 192.168.0.13
Control PC 192.168.0.14
Screen 2 RS20i 192.168.0.20
D-Cinema server 192.168.0.21
Digital Projector 192.168.0.22
Another network device 192.168.0.23
Control PC 192.168.0.24
Technical area Library server 192.168.0.200
Satellite server 192.168.0.201
Another server 192.168.0.202
Administrators PC 192.168.0.203