Appendix D: RS20i Product Specifications D-2 Document #: 9301H52900 Ver. 1.01
Connectors: Two DB25 Male (Ch1-8 and Ch9-16)
Digital Format: AES/EBU
Sample Rates: 48kHz, 96kHz and 192kHz
Analog Audio Outputs
Channels: 16 (fully routable as to input), common mapping with Digital Outputs
Balanced (can be connected unbalanced or single ended)
Connectors: Two DB25 Male (Ch1-8 and Ch9-16)
Level: 300mV with Volume at -15.0, +26dBu max (balanced)
Connector: 1 single ended RCA output, channel-selectable to drive an external monitor.
Adjustable Levels, to 300mV RMS
Connector: 1 single ended RCA output, summed output for the hearing impaired. -
Fixed Level Out, 300mV RMS
Audio EQ
Dirac Live® Room Optimization
12-Channel Dirac Live® room optimization (16-channel Dirac to be available in future
release)
Dirac Live® Installer kit sold separately
3rd Octave EQ
16 channels - 31 user-adjustable bandpass filters
Gain +/-6dB adjustable in 0.5dB steps
Frequencies range from 20Hz to 20kHz.
Parametric
16 channels with 3 user-adjustable parametric filters for shaping Subwoofer response.
Adjustable from 20 to 200Hz, gain +/-6dB in 0.1dB steps
Q range from 0.7 to 5.
Hi/Low/Bandpass Active Crossovers
Adjustable from 20Hz to 20kHz; adjustable slope of 6, 12, 18 or 24dB per octave (12
and 24dB filters are Linkwitz-Riley crossover)
Bass/Treble tone control
Adjustable +/-6dB per channel
Corner frequency for bass adjustable from 50Hz to 300Hz
Corner frequency for treble adjustable from 1.5kHz to 12.0kHz
Bass Management
Full or adjustable high pass settings for screen and surround speakers
Adjustable high pass filter for sub woofers
Support for 0 to 4 sub woofers
Optional phantom center
Page view 137