2.5.4 Power Supply
Warning: Before powering on the RS20i for the first time, verify that the correct input voltage
has been selected at the rear panel power entry module. Incorrect input voltage setting will
damage the RS20i.
The RS20i may be set for either 115V (105-130V operation) or 230V (215-260V operation).
Figure 14. Power Entry Module – Voltage Input Settings
2.5.4.1 Changing the Input Voltage Setting and Fuses
CAUTION: DOUBLE POLE/NEUTRAL FUSING
Open the fuse compartment door. A small flat blade screwdriver may be used to release the door.
Protect the RS20i metal finish, from damage by the screwdriver, with a rag or other soft item.
Figure 15. Power Entry Module – Releasing the Fuse Compartment Door
Remove the fuse block by freeing it with a small flat blade screwdriver. The block has slots for
this purpose in the top and bottom sides. Do not try to pry the block out from the sides, as this
will damage the block. Use a rag or other soft item to protect the RS20i metal finish.